NetCDF fields
A listing of fields saved in GXSM NetCDF files:
A listing of fields saved in GXSM NetCDF files:
Field name
FloatField
time
value
dimx
dimy
reftime
comment
title
username
dateofscan
rangex
rangey
rangez
dx
dy
dz
offsetx
offsety
alpha
contrast
bright
vrange_z
voffset_z
t_start
t_end
viewmode
basename
LInfo_dsc
LInfo_fmt
LInfo_fmo
LInfo_values
spm_scancontrol
extra_scan_info
sranger_info
sranger_mk2_hwi_bias
sranger_mk2_hwi_motor
sranger_mk2_hwi_mix0_current_set_point
sranger_mk2_hwi_mix1_voltage_set_point
sranger_mk2_hwi_mix2_aux2_set_point
sranger_mk2_hwi_mix3_aux3_set_point
sranger_mk2_hwi_mix0_current_mix_gain
sranger_mk2_hwi_mix1_voltage_mix_gain
sranger_mk2_hwi_mix2_aux2_mix_gain
sranger_mk2_hwi_mix3_aux3_mix_gain
sranger_mk2_hwi_mix0_current_mix_level
sranger_mk2_hwi_mix1_voltage_mix_level
sranger_mk2_hwi_mix2_aux2_mix_level
sranger_mk2_hwi_mix3_aux3_mix_level
sranger_mk2_hwi_mix0_current_mix_transform_mode
sranger_mk2_hwi_mix1_voltage_mix_transform_mode
sranger_mk2_hwi_mix2_aux2_mix_transform_mode
sranger_mk2_hwi_mix3_aux3_mix_transform_mode
sranger_mk2_hwi_move_speed_x
sranger_mk2_hwi_scan_speed_x
sranger_mk2_hwi_usr_cp
sranger_mk2_hwi_usr_ci
sranger_mk2_hwi_ldc_flag
sranger_mk2_hwi_frq_ref
sranger_mk2_hwi_IIR_f0_min
sranger_mk2_hwi_IIR_f0_max
sranger_mk2_hwi_IIR_I_crossover
sranger_mk2_hwi_LOG_I_offset
sranger_mk2_hwi_slope_compensation_flag
sranger_mk2_hwi_slope_x
sranger_mk2_hwi_slope_y
sranger_mk2_hwi_pre_points
sranger_mk2_hwi_XSM_Inst_VX
sranger_mk2_hwi_XSM_Inst_VY
sranger_mk2_hwi_XSM_Inst_VZ
sranger_mk2_hwi_XSM_Inst_VX0
sranger_mk2_hwi_XSM_Inst_VY0
sranger_mk2_hwi_XSM_Inst_VZ0
sranger_mk2_hwi_AC_amp
sranger_mk2_hwi_AC_frq
sranger_mk2_hwi_AC_phaseA
sranger_mk2_hwi_AC_phaseB
sranger_mk2_hwi_AC_avg_cycels
Description
time of scan in Unix t_end-t_start (see below)
dimx x values of scan in A
dimy y values of scan in A
datetime@start DoW M dd hh:mm:ss yyyy
Comment box at time of save
datetime@start DoW M dd hh:mm:ss yyyy
rangex in A
rangey in A
rangez in A
dx in A
dy in A
dz in A
image x offset in A
image y offset in A
Vrange_z value when img saved in A or V
Vrange_z value when img saved in A or V
start date/time in Unix time
end date/time in Unix time
viewmode 1=direct, 2=quick, 64=plane
directory/filename of original save file
check box in scanctr topdown bottomup etc
a lot of info from SR DSP control
Bias when scan is saved V
*newer version only
Current set point at end of scan
Voltage set point at end of scan
0=OFF, 1=Linear, 3=LOG, 9=Fuzzy
0=OFF, 1=Linear, 3=LOG, 9=Fuzzy
0=OFF, 1=Linear, 3=LOG, 9=Fuzzy
0=OFF, 1=Linear, 3=LOG, 9=Fuzzy
move speed in A/s
actual scan speed in A/s
proportional gain when saved
integral gain when saved
*newer version only
*newer version only
*newer version only
Piezo drive setting value
Piezo drive setting value
Piezo drive setting value
Piezo drive setting value
Piezo drive setting value
Piezo drive setting value